Active implantable medical devices — Four-pole connector system for implantable cardiac rhythm management devices — Dimensional and test requirements
Edition 2
2020-11
Preview
ϲʿ 27186:2020
72920
Indisponible en ڰç
ʳܲé (Edition 2, 2020)

ϲʿ 27186:2020

ϲʿ 27186:2020
72920
Langue
Format
CHF 216
Convertir les francs suisses (CHF) dans

éܳé

This document specifies a four-pole connector system for implantable cardiac rhythm management (CRM) devices which have pacing, electrogram sensing and/or defibrillation functions. This document includes requirements for the connector portion of an implantable lead as well as for the mating connector cavity attached to an implantable pulse generator. Essential dimensions and performance requirements are specified together with appropriate test methods.

NOTE The safety, reliability, biocompatibility, biostability and function of any particular part are the responsibility of the manufacturer.

This document is not intended to replace or provide alternatives for unipolar or bipolar connector standards that currently exist (such as ϲʿ 11318 and ϲʿ 5841-3).

This document is not applicable to high-voltage systems with intended outputs greater than 1 000 V and/or 50 A. This document is not applicable to systems which include sensors or unique electrodes that are not capable of conventional pacing, electrogram sensing and/or defibrillation functions.

This document does not specify all connector features.

This document does not address all aspects of functional compatibility, safety or reliability of leads and pulse generators assembled into a system.

NOTE Lead and pulse generator connector systems not conforming to this document can be safe and reliable and can have clinical advantages.

Informations générales

  •  : ʳܲé
     : 2020-11
    : Norme internationale à réviser [90.92]
  •  : 2
  • ϲʿ/TC 150/SC 6
    11.040.40 
  • RSS mises à jour

Prochaine édition en cours d'élaboration

Draft
International Standard
ϲʿ/DIS 27186
Dispositifs médicaux actifs implantables — Systèmes de branchement à quatre pôles pour dispositifs implantables de gestion du rythme cardiaque — Exigences de dimensions et d'essai
Reference number
ϲʿ/DIS 27186
Edition 1
Projet Norme internationale

ϲʿ/DIS 27186

Dispositifs médicaux actifs implantables — Systèmes de branchement à quatre pôles pour dispositifs implantables de gestion du rythme cardiaque — Exigences de dimensions et d'essai

ϲʿ/DIS 27186

ϲʿ/DIS 27186
86332
Langue
Format
CHF 129
Convertir les francs suisses (CHF) dans

Vous avez une question?

Consulter notre Aide et assistance

Service à la clientèle
+41 22 749 08 88

Horaires d’ouverture:
De lundi à vendredi - 09:00-12:00, 14:00-17:00 (UTC+1)