Reference number
ΟγΈΫΑωΊΟ²ΚΏͺ½±/TR 12389:2009
Technical Report
ΟγΈΫΑωΊΟ²ΚΏͺ½±/TR 12389:2009
Methods of testing cement β€” Report of a test programme β€” Chemical analysis by x-ray fluorescence
Edition 1
2009-05
Technical Report
Read sample
ΟγΈΫΑωΊΟ²ΚΏͺ½±/TR 12389:2009
51402
Published (Edition 1, 2009)
This publication was last reviewed and confirmed in 2021. Therefore this version remains current.

ΟγΈΫΑωΊΟ²ΚΏͺ½±/TR 12389:2009

ΟγΈΫΑωΊΟ²ΚΏͺ½±/TR 12389:2009
51402
Language
Format
CHF 194
Convert Swiss francs (CHF) to

Abstract

ΟγΈΫΑωΊΟ²ΚΏͺ½±/TS 12389:2009 describes the results of the inter-laboratory testing of the chemical analysis of cement by x-ray fluorescence. In the first instance, the inter-laboratory testing was carried out in Japan and Asian countries in accordance with JIS R 5204:2002. A total of 30 laboratories, 16 in Japan and 14 outside Japan, participated in the original testing programme. A further 12 European laboratories participated in tests with the same materials in 2005 in accordance with EN 196-2, a development by CEN/TC 51/WG 15/TG 1 of JIS R 5204. The latest version, developed as ΟγΈΫΑωΊΟ²ΚΏͺ½± 29581-2, is, as of the date of publication of this Technical Report, in the process of being circulated for technical enquiry.

The test samples used were Portland cement conforming to CEM I of EN 197-1 and a mixture of Portland cement and blast furnace slag. The mixture corresponded to the composition of Portland blast furnace slag cement, class B, specified in JIS R 5211 and CEM III/A of EN 197-1. Cement reference materials for x-ray fluorescence analysis (No. 601A) are used for the calibration standards, and certified reference materials JCA-CRM-1 and JCA-CRM-2 are used as the validation materials.

Constituents analysed include SiO2, Al2O3, Fe2O3, CaO, MgO, SO3, Na2O, K2O, TiO2, P2O5, MnO and SrO. The loss on ignition is also determined.

The ΟγΈΫΑωΊΟ²ΚΏͺ½± round robin is a method-performance study conducted under close to optimum conditions with clear calibration and measurement guidelines. This is conducive to producing β€œbest practice” values representative of the ideal situation. However, ΟγΈΫΑωΊΟ²ΚΏͺ½± 29581-2 is intended for use under everyday conditions in laboratories that operate to β€œgood practice”. The results are presented for some international round robins carried out by a large number of laboratories demonstrating the suitability of ΟγΈΫΑωΊΟ²ΚΏͺ½± 29581-2 as a means for comparing the everyday performance of laboratories.

General information

Got a question?

Check out our Help and Support

Check out our FAQs

Customer care
+41 22 749 08 88

Opening hours:
Monday to Friday - 09:00-12:00, 14:00-17:00 (UTC+1)